Residential Load Calculation 220.82
- Code basis
- 220.82 (optional method)
- Also see
- 220.57 EVSE, 230.79(C)
- Output
- Service / feeder VA and amps
- Common add
- EV charger load
The Procedure
5 steps, in the order the code applies them.
Step 1
Assemble the general load
Include general lighting from floor area, the small-appliance and laundry circuit allowances, and the fixed appliances that belong in the general load.
Step 2
Add EVSE under the adopted edition
Enter EV charging per the edition in force. The 2023 path includes a dedicated EVSE treatment that earlier editions do not share the same way.
Step 3
Apply the optional-method demand factor
Demand-factor the general load in the order the optional method requires before bringing HVAC into the total.
Step 4
Add the largest heating or cooling item
After the general load, add the largest of the applicable heating or cooling loads — not both at full value when the method takes the larger.
Step 5
Convert VA to service amperes
Divide by the service voltage to get amperes, then compare with standard service sizes and local utility minimums.
The order matters
General lighting, small-appliance and laundry circuits, appliances and EVSE form the general load before the demand factor is applied.
Heating and cooling are handled after that, and only the largest applicable item is added.
Edition-sensitive EVSE
The calculator treats the 7200 VA EVSE minimum as a 2023-path input and warns when an earlier edition is selected.
Confirm the EVSE rule against the edition adopted by the AHJ before the service size is submitted.
Decision Guide
The choices that change the answer, and how to make them.
Do not mix optional and standard methods midstream
Pick 220.82 or the standard method and stay with it. Mixing demand factors from both produces a number neither method recognizes.
Nameplate before brochure watts
Appliances enter at nameplate ratings. Marketing recovery rates and cooking watts are the wrong inputs.
Floor area is the lighted area rule in use
Use the floor-area basis the adopted edition and AHJ expect. Understating area quietly understates the general lighting load.
FAQs
What is the NEC 220.82 optional load calculation?
Do I include both heat and air conditioning at full value?
How does an EV charger enter a 220.82 calculation?
Calculated against the NEC 2023 edition using 220.82, 220.57, 230.79(C). Confirm the edition adopted by your AHJ, which may differ and may carry local amendments.
Not covered by this tool
- Motor, air-conditioning and welder circuits, which are sized under their own articles.
- Conductors in free air and photovoltaic circuits.
- Parallel conductor sets, taps and busbars.
- Local amendments, which can be stricter than the published code.
Data last verified